To obtain the user verification mode.
- Parameters
-
| Parameter description:
name | type | param direction | description of param |
dwMachineNumber | LONG | [in] | Machine ID |
dwEnrollNumber | BSTR | [in] | User ID |
VerifyStyle | LONG* | [out] | Verification mode |
Reserved | BSTR* | [out] | Reserved |
|
- Returns
- Value description:
name | type | description of value |
True | BOOL | Function execution success |
False | BOOL | Function execution failure |
- See also
- Attention
- 1. The VerifyStyle parameter specifies the verification mode. The values are described as follows:
Group Verify = 0
FP/PW/RF = 128
FP = 129
PIN = 130
PW = 131
RF = 132
FP/PW = 133
FP/RF = 134
PW/RF = 135
PIN&FP = 136
FP&PW = 137
FP&RF = 138
PW&RF = 139
FP&PW&RF = 140
PIN&FP&PW = 141
FP&RF/PIN = 142
- The Reserved parameter is reserved and not used at present.
- Note
- This interface is applicable to the new architecture firmware.